P/N: ETI0019-2110E
Tactical Wheeled Carry-On UPS
Rating: 1000 VA, 750 Watt

Input: 85-270 VAC, 45-70 Hz
Output: 120 VAC, 50/60 Hz
Transportable Tactical 1 kVA UPS
    schematic

Recessed 100 G shock rated circuit breaker (CB1)
Optional cold start switch available to turn on w/o AC present Four AC outputs standard, several optional configurations
AC OUTPUT
Output voltage: 120 VAC true sinewave output standard
Output rating: UPS 1000 VA, 750 watts standard, 
Non-linear load capacity: UPS Up to 100% non-linear load capability w/o derating
Output voltage regulation: UPS ± 3.0% static regulation of nominal
± 4.0% dynamic (0 to 50% load step)
Overload surge capacity: UPS 110% for 10 minutes; 125% for 30 seconds
Harmonic distortion: UPS Less than 5.0% into 100% non-linear load
Output frequency: UPS 60 Hz or 50 Hz switch selectable
± 2.5% synchronized to utility
± 1.0% w/ utility not available
Operational status AC Input status, UPS operational, UPS alarm, Battery level,
Low battery, Load level, Overload, Warm/Hot temperature, Battleshort LEDs, +90 dB audible alarm w/audible on/off switch
AC INPUT
Input voltage selection: Autoranging from nominal 85 VAC to 270 VAC
Input voltage tolerance: UPS +15% -25%, or 85-140 and 170-280 
@ full load without using battery, to 70 VAC @ 75% load
Input frequency: From 45 Hz to 70 Hz standard, optional to 440 Hz
Input power factor: Better than 99% typically
Input/output isolation: up to 120 dB common mode, <1.0 ma leakage
Input transient suppression: Complies with IEEE 587, UL 1449 and Mil Std 1399
Input control/protection:
Input power connections: One IEC320 male, 3 pin
INTERNAL BATTERY
Internal battery type: Maintenance free immobilized electrolyte,
Flame retardant materials (Oxygen Index 28+)
Internal battery life: Rated for continuous service life of 5 years
Internal battery protection: Recessed 100 G shock rated circuit breaker (CB2)
Internal battery time: 5+ minutes @ 750 watt load, 12+ minutes @ 50%
Internal battery recharge: Recharged to nominal in <8 hours
Internal battery replacement: Hot swap drawout/plug-in module from front of unit
<3 minutes to change battery modules
Battery expansion: Up to 24 hours w/ optional Battery Expansion Modules
DISTRIBUTION PANEL
Output circuits: Four
Output receptacles: AC output  NEMA 5-15R, various options
MECHANICAL
Dimensions (H x D x W): UPS 21.75 x 8.99 x 13.75 in (552 x 228 x 349 mm)
Unit weight 50 lb. (23 kg)
Audible noise: Less than 47 dB @ 5.0 ft., ANSI "A" scale
Cooling type: High capacity, positive pressure, forced air
Air intake filter: Washable metal filter media, others optional
ENVIRONMENTAL
Storage temperature: -40° to 158° F ambient (-40° to 70° C)
Operating temperature: 32° to 126° F ambient ( 0° to 52° C), lower/ higher optional
Operating humidity: 0 to 95% relative humidity (non-condensing)
Storage elevation: Up to 40,000 ft (12,192 m), higher optional
Operating elevation: Up to 10,000 ft (3,048 m), higher optional
STANDARDS
United States: Meets UL-1778 standard for UPS equipment,
Meets MIL-STDs 1275, 167-1, 454, 810, 1399-300A
& MIL-S-901
Canada: CSA C22.2 No. 107 UPS safety requirements
EMI Protection: EMI/RFI FCC Part 15, Class A; EN55022
OPTIONAL ACCESSORIES
  Cold Start, Alternate I/O Configurations, Battery Expansion,
Battery Charger/Conditioner, Power Distribution Units